This bar serves to notify visitors of important updates

Products

Explore product specifications, available configurations, compatible instruments, and regulatory documentation for this product.

Home Joint Prostheses Ceramic Acetabular Liner
Ceramic Acetabular Liner
Ceramic Acetabular Liner
Ceramic Acetabular Liner
Ceramic Acetabular Liner
  • Geasure Medical

  • 1

  • ISO 13485 \ CE \ FDA 510(k) Cleared \ Free Sale Certificate\ MDSAP

  • Ceramic

  • Custom service supported

  • 7–14 Days (OEM: 15–30 Days)

  • Sterile packaging or non-sterile

Inquire

Ceramic Acetabular Liner  Introduction

10-.jpg

The Ceramic Acetabular Liner from Geasure Medical is a bearing component designed for use in a compatible total hip replacement system. According to the 2026 Geasure Joint Product catalog, the liner is made from BIOLOX® delta fourth-generation ceramic composite material, offering wear resistance, lubrication properties, and biocompatibility. Multiple size configurations are listed to accommodate compatible acetabular cup and femoral head combinations. Geasure Medical supports orthopedic distributors, medical device importers, and OEM/ODM partners seeking hip joint implant solutions.

 

Ceramic Acetabular Liner Key Features

  • Fourth-generation ceramic composite: The catalog identifies BIOLOX® delta ceramic composite as the liner material.

  • Wear resistance: Ceramic bearing surfaces are designed for wear performance in compatible hip arthroplasty systems.

  • Lubrication properties: The ceramic bearing surface is designed to support articulation within the approved implant combination.

  • Biocompatibility: The catalog highlights the material’s biocompatibility.

  • Multiple size configurations: Several liner size combinations are listed in the product catalog.

  • System compatibility: Intended for use with compatible acetabular cups and femoral heads; exact combinations must be confirmed before ordering.

BIOLOX® is a third-party brand designation. Confirm applicable material sourcing, authorization, and trademark requirements before using brand-specific claims in commercial materials.

 

Ceramic Acetabular Liner  Applications and Indications

The Ceramic Acetabular Liner is designed as a bearing component for use in a compatible total hip arthroplasty system.

Potential application areas include:

  • Ceramic-on-ceramic or other specifically approved hip bearing configurations, where applicable

  • Hip joint reconstruction product portfolios

  • Orthopedic implant sourcing for distributors and medical device importers

  • Component selection for compatible acetabular cup systems

The permitted bearing combinations, clinical indications, and patient-selection criteria must follow the product’s approved instructions for use (IFU).

 

Ceramic Acetabular Liner  Specifications

Product No.

Size

Listed Diameter (mm)

A470102

38–28/46

28

A470104

40–32/48

32

A470105

42–32/50

32

A470107

44–36/52

36

A470108

46–36/54

36

A470109

48–36/56–60

36

Parameter

Specification

Product name

Ceramic Acetabular Liner

Catalog designation

Insert (Ceramic)

Component type

Hip prosthesis bearing component

Material stated in catalog

BIOLOX® delta fourth-generation ceramic composite

Available configurations

Six listed product numbers

Listed diameter options

28, 32, 36 mm

Compatible acetabular cups

Confirm using the approved compatibility matrix

Compatible femoral heads

Confirm using the approved compatibility matrix

Sterilization and packaging

Refer to product labeling and technical documentation

Specification note: The catalog’s Size column combines multiple dimensions, while the Diameter column lists 28, 32, or 36 mm. Keep the original size notation unless Geasure’s technical team confirms the meaning of each value. Do not interpret the slash-separated values as independently interchangeable sizes.

 

Compatible Components and Instruments

A ceramic acetabular liner must be selected as part of a compatible hip replacement system. Before confirming an order, verify:

  • Acetabular cup model and internal geometry

  • Compatible femoral head diameter and material

  • Approved bearing combination

  • Relevant trial components and assembly instruments

  • Product-specific surgical instructions and technical documentation

The 2026 catalog also lists cementless acetabular cups and femoral heads. Their appearance in the same catalog does not, by itself, establish compatibility with every ceramic liner size.

 

Why Source Hip Joint Implants from Geasure Medical?

Geasure Medical manufactures orthopedic implants and surgical instruments for international medical device markets. Its portfolio includes hip joint reconstruction, trauma fixation, spine implants, and related orthopedic instruments.

For distributors and medical device companies evaluating ceramic acetabular liners, cooperation can include:

  • Product model and size information

  • Technical specifications and compatibility confirmation

  • Available regulatory documentation

  • OEM/ODM project discussions

  • Packaging, labeling, and supply planning

Any material-brand, certification, or regulatory claim should be supported by documentation applicable to the specific product being supplied.

 

Distributor & OEM/ODM Cooperation

Geasure Medical works with orthopedic distributors, medical device importers, and established medical brands to provide hip joint implant solutions for their target markets. Our team can support product evaluation by sharing available specifications, model and size information, and details of compatible acetabular cups and femoral heads.

For OEM/ODM projects, we welcome discussions about product requirements, packaging and labeling options, target-market documentation, minimum order quantities, and production lead times, subject to project evaluation and applicable regulatory requirements.

Contact Geasure Medical to discuss your requirements for ceramic acetabular liners, your target market, preferred size configurations, and estimated order quantities.

Suggested inquiry form fields

  • Target country or market

  • Required product number and size

  • Compatible acetabular cup model

  • Required femoral head diameter and material

  • Estimated order quantity

  • Technical and regulatory documentation requirements

  • OEM/private-label requirements

  • Company name and contact details

Ceramic Acetabular Liner FAQ

What is a ceramic acetabular liner?

A ceramic acetabular liner is a bearing component used within a compatible hip replacement system. It forms part of the articulation between the acetabular component and the selected femoral head.

What material is used in the Geasure ceramic liner?

The 2026 Geasure Joint Product catalog identifies BIOLOX® delta fourth-generation ceramic composite material. Confirm the material specification and applicable sourcing documentation for the exact product before making procurement decisions.

What are the advantages of a ceramic hip bearing surface?

Ceramic bearing surfaces are valued for their wear characteristics and bearing performance in appropriately designed hip arthroplasty systems. Actual clinical performance depends on the complete implant combination, surgical technique, and patient-specific factors.

What sizes are available?

The catalog lists six product numbers, from A470102 to A470109, with diameter entries of 28, 32, or 36 mm. Refer to the specification table and verify the exact cup and femoral head compatibility before ordering.

Can the ceramic liner fit any cementless acetabular cup?

No. Ceramic liners are designed for specific acetabular cup geometries and locking mechanisms. Confirm the exact compatible cup model and size with Geasure Medical before placing an order.

Does Geasure Medical support OEM/ODM cooperation?

Geasure Medical welcomes OEM/ODM discussions with orthopedic distributors, medical device importers, and established medical brands. Project requirements, labeling, packaging, documentation, and supply conditions are assessed individually.

How can distributors request a quotation?

Send Geasure Medical your target market, required product number and size, compatible cup model, expected order quantity, and documentation requirements. The team can then review the inquiry and confirm applicable specifications and supply details.