Revision Cemented Femoral Stem Introduction
The JC Revision Cemented Femoral Stem is designed for hip revision procedures and proximal femoral fractures. Its design allows the stem to settle within the bone cement mantle to help regain stability. Available in four sizes, with stem lengths ranging from 170 mm to 230 mm, it supports different surgical requirements. Please contact Geasure Medical for detailed specifications and customization options.
Revision Cemented Femoral Stem Key Features
Designed for Revision Procedures: Intended for use in hip revision cases and proximal femoral fractures.
Cemented Fixation: Designed to settle within the bone cement mantle to help regain prosthesis stability, as described in the product catalog.
Multiple Size Options: Available in four listed sizes to support different surgical requirements.
Extended Stem Lengths: Listed lengths range from 170 mm to 230 mm.
Manufacturer Support: Geasure Medical can provide product specifications and discuss OEM/ODM requirements with qualified distributors and medical device partners.
Revision Cemented Femoral Stem Specifications
The following specifications are transcribed from the JC Revision Cemented Stem table in the product catalog.
Product Name | Product No. | Size | Length (mm) |
|---|
JC Revision Cemented Femoral Stem | A060301 | 9 | 170 |
JC Revision Cemented Femoral Stem | A060302 | 10 | 190 |
JC Revision Cemented Femoral Stem | A060303 | 11 | 210 |
JC Revision Cemented Femoral Stem | A060304 | 12 | 230 |
Note: The catalog does not specify the stem material, coating, neck geometry, or complete dimensional tolerances on this page. Please confirm these details with Geasure Medical before publishing additional technical specifications.
Distributor & OEM/ODM Cooperation
Geasure Medical works with orthopedic distributors, medical device importers, and established medical brands to evaluate suitable orthopedic implant solutions for their target markets.
Our team provides available product specifications, model information, and details of compatible instruments to support product evaluation and procurement discussions. Depending on project requirements, we can also discuss OEM/ODM cooperation, packaging and labeling options, minimum order quantities (MOQs), and production lead times.
Contact Geasure Medical to discuss your target market, required implant specifications, and estimated order quantities.
Topics for Distributor Discussion
Available product models and size ranges
Technical specifications and product catalogs
Compatible instruments and system configurations
OEM/ODM services and packaging requirements
Minimum order quantities and production lead times
Applicable regulatory documentation for the target market
FAQ—Revision Cemented Femoral Stem
What is the JC Revision Cemented Femoral Stem?
The JC Revision Cemented Femoral Stem is a hip implant designed for revision procedures and proximal femoral fractures. According to the Geasure Medical product catalog, the stem is designed to settle within the bone cement mantle to help regain stability.
What are the indications for the JC Revision Cemented Stem?
The product catalog lists proximal femoral fractures and hip revision cases as intended applications. Final implant selection and use should be determined by qualified orthopedic surgeons according to the patient's condition and the applicable product instructions.
What sizes are available for the JC Revision Femoral Stem?
The catalog lists four models: A060301, A060302, A060303, and A060304. Their corresponding sizes are 9, 10, 11, and 12, with stem lengths of 170 mm, 190 mm, 210 mm, and 230 mm, respectively.
What is the difference between a cemented revision stem and a cementless revision stem?
A cemented femoral stem is designed for fixation using bone cement, whereas a cementless stem relies on a different fixation approach. The JC Revision Cemented Femoral Stem is listed as a cemented product. The appropriate fixation method depends on the surgical plan, bone condition, and the specific implant system.
Is the JC Revision Cemented Femoral Stem suitable for every hip revision case?
No. Suitability depends on factors such as the patient's bone condition, the revision requirements, and the surgeon's treatment plan. The product catalog identifies revision cases as an intended application, but it does not establish suitability for every revision scenario.
Can distributors obtain technical specifications for the JC Revision Cemented Stem?
Yes. Distributors and medical device importers can contact Geasure Medical to request available technical specifications, product catalogs, model details, and applicable regulatory documentation for product evaluation.
Does Geasure Medical offer OEM/ODM services for hip implants?
Geasure Medical welcomes OEM/ODM discussions with orthopedic distributors, importers, and medical brands. Depending on project feasibility, discussions may cover product specifications, packaging and labeling, minimum order quantities, and production lead times.
How can I request a quotation for the JC Revision Cemented Femoral Stem?
Please contact Geasure Medical with your required model numbers, quantities, target market, and any relevant technical or regulatory requirements. Our team can review the request and discuss available product information and procurement arrangements.