Posterior Cervical Screw-Rod Fixation System Introduction
The Cervical Posterior Screw-Rod Fixation System is designed for posterior fixation procedures involving the cervical spine. Its system concept combines screws and connecting components to support configuration planning across different surgical requirements.
Posterior Cervical Screw-Rod Fixation System Key Features and Advantages
Anatomical Occipito-Cervical Contour
A pre-bent 135° design at the occipito-cervical junction is intended to follow the anatomy of this transition area and support construct planning.
Polyaxial Screw Design
The screw design allows up to 55° of unidirectional angulation, offering flexibility when planning screw and rod alignment.
Negative-Angle Thread Design
The thread design is intended to help resist screw-arm expansion, a useful design consideration when evaluating fixation components.
Plate-Clamp Cross-Link Option
A plate-clamp cross-link is designed to facilitate connection when screws are not arranged in a straight line.
Focused Cervical Product Offering
The system gives distributors a dedicated cervical posterior fixation option to assess alongside other cervical and spine products in their portfolio.
颈椎后路钉棒固定系统 · 适应症海报
Spine Center · Posterior Cervical Fixation
Posterior Cervical Screw-Rod Fixation System Applications
Cervical Spinal Instability
Cervical Spondylosis with Myelopathy
Cervical Spinal Stenosis
Cervical Trauma and Fractures
Cervical Deformity Correction
DEPARTMENT OF ORTHOPEDIC SURGERY · SPINE UNIT
REF: CERV-2025-04
Posterior Cervical Screw-Rod Fixation System Specifications
Cervical polyaxial screw
Image
Diameter(mm)
Length(mm)
3.5
10/12/14/16/18/20/22/24/26/28/30/32
4.0
12/14/16/18/20/22/24/26/28/30/32/34
Polished Rod Cervical polyaxial screw
Image
Diameter(mm)
Length(mm)
4.0
20/22/24/26/28/30/32/34/36
Cross-Linkage
Image
Diameter(mm)
Length(mm)
3.5
20-28
28-36
36-44
40-52
Set Screw
Image
Diameter(mm)
M6
Straight connecting rod ll
Image
Diameter(mm)
Length(mm)
3.5
150
180
200
240
Posterior Cervical Screw-Rod Fixation System Compatible Instruments
No.
Name
Specification
Quantity
Code
1
Open cone
Open cone Φ2.0
1
90011620
2
Circuit breaker
Φ 2.1
1
90010302
3
Circuit breaker
Countersink reamer
1
90010303
4
nailer
Universal top nail screwdriver SW2.5
2
90010304
5
Hook pliers
Cross hook holder
1
90010305
6
Reset forceps
-
1
90010306
7
Drill guide
Fixed drilling guide Φ4.1
1
90010307
8
Drill guide
Adjustable drilling guide Φ4.1
1
90010308
9
Counter wrench
Counter sleeve
1
90010309
10
Quick-load handle
Quick-change handle
2
90011609
11
Bone measuring apparatus
Die stick 24cm
1
90010310
12
Wire shear
Ratchet bar cutter forceps
1
90010311
13
Bar bending pliers
-
1
90010312
14
Rod holding forceps
Rod holding pliers Φ3.5
1
90010313
15
Rotating bar pliers
Power rod wrench Φ3.5
1
90010314
16
Wire shear
Internal bar cutter forceps
1
90010315
17
Compression forceps
Internal compression forceps
1
90010316
18
Orthopedic spreader forceps
Internal spinner forceps
1
90010317
19
Orthopedic wrench
Push wire locking driver SW2.5
1
90010318
20
Orthopedic wrench
Cross interlocking wrench
1
90010319
21
Medical ruler
Transverse measuring stick
1
90010320
22
Orthopedic wrench
Hold the wire driver SW2.5
2
90010321
23
Vertebral reset device
Internal bar Bender (left)
1
90010322
24
Vertebral reset device
Internal bar Bender (right)
1
90010323
25
sleeve
Support sleeve Φ5.1
1
90010324
26
Orthopedic bit
Bit Φ2.4
1
90010325
27
Tap for bone
Adjustable tap Φ3.5
1
90010326
28
Tap for bone
Adjustable tap Φ4.0
1
90010327
29
Bone probe
Single head probe
1
90010328
30
Guide needle
Spherical SW2.5
3
90010329
31
Guide needle
Column SW2.5
3
90010330
32
Orthopedic clamp
Developing needle implant SW2.5
1
90010331
33
Depth sounder
Sounding scale
1
90010332
34
Implant box
Top box
1
90010333
35
Implant box
Screw box
1
90010334
36
Orthopedic locator
Nail adjuster
1
90010335
37
Instrument box
1
90010336
Geasure Medical
Manufacturer Strength
Manufacturer Overview
Manufacturing & Project Support
A concise overview of precision manufacturing, quality management, regulatory documentation, and OEM/ODM collaboration available to distributors and project partners.
01 · Manufacturing Capability
Precision Manufacturing
A Japanese Mazak five-axis machining center supports complex surfaces, multi-angle features, and precision-fit structures while reducing repeated setups and supporting batch consistency.
Five-axis machining
Complex geometries
Controlled production
Batch traceability
02 · Quality Management
Process-Wide Quality Control
Quality activities cover incoming material verification, first-article review, in-process checks, final inspection, release, and traceable batch documentation.
Inspection reports
Material certificates
Certificates of conformity
Batch records
03 · Regulatory Documentation
Documents for Applicable Markets
Available regulatory support can be reviewed against the target product, model, classification, intended market, and current document validity before an order is placed.
ISO 13485
CE
FDA 510(k) Cleared
Free Sale Certificate
MDSAP
Availability and scope must be confirmed for the specific product and intended market.
04 · OEM / ODM Support
Customization & Project Evaluation
Project communication may cover dimensions, instrument configuration, surface treatment, identification, packaging, documentation, technical feasibility, validation, quantity, cost, and lead time.
Requirement intake
Technical review
Proposal confirmation
Sample validation
Production delivery
Document note: Equipment, certificates, registrations, product scope, and document availability must be confirmed against current valid records and the agreed project scope. Images are illustrative and should be replaced with verified facility photography when available.
Posterior Cervical Screw-Rod Fixation System FAQ
Question: What is the Cervical Posterior Screw-Rod Fixation System?
Answer: It is a cervical spine product system designed for posterior fixation procedures.
Question: Can I request configuration and specification details?
Answer: Yes. Contact Geasure Medical with your product requirements to discuss the relevant configuration and specifications.
Question: Are matching instruments available?
Answer: Contact the team to discuss the instruments and configuration relevant to your project.
Question: Can this system be used with components from another brand?
Answer: Cross-brand compatibility should not be assumed. Confirm the exact components and compatibility information with the relevant manufacturer before planning a system.
Question: How can a distributor discuss cooperation?
Answer: Share your target market, product scope, estimated quantity, and contact details with Geasure Medical to begin a distributor discussion.
Question: How do I discuss an OEM/ODM project?