Effectively expand the volume of thecervical canal.
Fully relieve spinal cord symptomsof spinal stenosis.
Reduce the occurrence of reopeningafter laminoplasty.
![]() |
Changzhou Geasure Medical Apparatus and Instruments Co., Ltd. | |||
| Vertebral plate | ||||
| Name | Picture | Specification | Material | Code |
| Hinge plate-3 | ![]() |
2 Hole | Ti | 20370023 |
| Bone Graft Plate-3 | ![]() |
2 Hole 8 | Ti | 20361482 |
| 2 Hole 10 | Ti | 20361502 | ||
| 2 Hole 12 | Ti | 20361522 | ||
| 2 Hole 14 | Ti | 20361542 | ||
| 2 Hole 16 | Ti | 20361562 | ||
| 2 Hole 18 | Ti | 20361582 | ||
| Open Door Plate-3 | ![]() |
2 Hole 10×7 | Ti | 20050072 |
| 2 Hole 12×7 | Ti | 20052072 | ||
| 2 Hole 14×7 | Ti | 20054072 | ||
| 2 Hole 16×7 | Ti | 20056072 | ||
| 2 Hole 8×5 | Ti | 20048052 | ||
| 2 Hole 10×5 | Ti | 20050052 | ||
| 2 Hole 12×5 | Ti | 20052052 | ||
| 2 Hole 14×5 | Ti | 20054052 | ||
| 2 Hole 16×5 | Ti | 20056052 | ||
| 2 Hole 18×5 | Ti | 20058052 | ||
| Bridge Plate-3 | ![]() |
34×12×15.5 | Ti | 20385242 |
| 34×14×16.5 | Ti | 20385462 | ||
| 36×12×15.5 | Ti | 20385243 | ||
| 36×14×16.5 | Ti | 20385463 | ||
| 34×16×17.5 | Ti | 20385682 | ||
| 34×18×18 | Ti | 20385892 | ||
| 36×16×17.5 | Ti | 20385683 | ||
| 36×18×18 | Ti | 20385893 | ||
| Open Door Plate-4 | ![]() |
2 hole 8×5 | Ti | 20068052 |
| 2 hole 10×5 | Ti | 20070052 | ||
| 2 hole 12×5 | Ti | 20072052 | ||
| 2 hole 14×5 | Ti | 20074052 | ||
| 2 hole 16×5 | Ti | 20076052 | ||
| 2 hole 18×5 | Ti | 20078052 | ||
| 2 hole 10×7 | Ti | 20070072 | ||
| 2 hole 12×7 | Ti | 20072072 | ||
| 2 hole 14×7 | Ti | 20074072 | ||
| 2 hole 16×7 | Ti | 20076072 | ||
| Bone Graft Plate-4 | ![]() |
2 hole 8 | Ti | 20361682 |
| 2 hole 10 | Ti | 20361702 | ||
| 2 hole 12 | Ti | 20361722 | ||
| 2 hole 14 | Ti | 20361742 | ||
| 2 hole 16 | Ti | 20361762 | ||
| 2 hole 18 | Ti | 20361782 | ||
| Bridge Plate-4 | ![]() |
34×12×15.5 | Ti | 20387242 |
| 34×14×16.5 | Ti | 20387462 | ||
| 36×12×15.5 | Ti | 20387243 | ||
| 36×14×16.5 | Ti | 20387463 | ||
| 34×16×17.5 | Ti | 20387682 | ||
| 34×18×18 | Ti | 20387892 | ||
| 36×16×17.5 | Ti | 20387683 | ||
| 36×18×18 | Ti | 20387893 | ||
| Self-tapping Screw-1 | ![]() |
2.6×5 | TC4 | 20413051 |
| 2.6×7 | TC4 | 20413071 | ||
| 2.6×9 | TC4 | 20413091 | ||
| 2.6×11 | TC4 | 20413111 | ||
![]() |
3.0×5 | TC4 | 20414051 | |
| 3.0×7 | TC4 | 20414071 | ||
| 3.0×9 | TC4 | 20414091 | ||
| 3.0×11 | TC4 | 20414111 | ||

| Cervical cage Instrument | |||
| Name | Specification | Quantity | code |
| Mold test | (I)8/10 | 1 | 90011501 |
| Mold test | (II)12/14 | 1 | 90011502 |
| Mold test | (III)16/18 | 1 | 90011503 |
| Cervical curet | 210 | 1 | 90011504 |
| Plate holder | 210 | 1 | 90011505 |
| Orthopedic bit | φ1.5 | 2 | 90011506 |
| Bone holding forceps | 215 | 1 | 90011507 |
| Open cone | φ1.2 | 1 | 90011508 |
| Nail holder for orthopedics | 120 | 1 | 90011509 |
| Quick-load handle | 160 | 2 | 90011510 |
| Orthopedic wrench | 160 | 2 | 90011511 |

Features and Benefits of Cervical Laminoplasty System
Cervical laminoplasty can effectively expand the volume of the spinal canal and relieve the symptoms of spinal cord compression in multiple segments of cervical spondylosis ,or spinal nerve root symptoms. The main indications are degenerative spondylolisthesis of cervical vertebra, ossificationof posterior longitudinal ligament of cervical vertebra ,and similar diseases.
Bridge plate (pure titanium material ,length of 8-18mm, 2mm interval):
● Pre-cutting ,pre-forming design.
● Arch bridge design provides maximum fixation force for forming lamina and ensures spinalcanal enlargement.
● The central oval hole design of the plate provides convenience for precise adjustment of bone graft screw.
Hinge plate (pure titanium material):
● Small angle design to stabilize the instability or displacement of the hinged side of the lamina.
Bone graft plate (pure titanium material, length of 8-18mm, 2mm interval):
● Pre-cutting ,pre-forming design.
● The central oval hole design of the plate provides convenience for precise adjustment of bone graft screw.
● Multiple screw holes selection to provide more freedom for screw insertion.
Open door plate (pure titanium material ,length of 8-18 mm, 2mm interval):
● Pre-cutting ,pre-forming design.
● Opening design is easy to install and fix, providing unique stability.
● Multiple screw holes selection to provide more freedom for screw insertion.
● Foot-retaining design helps to achieve immediate stability in plate planting.
● Horizontal /vertical foot design,fixed on the lateral cervical mass.
● Normal opening and large opening design,suitable for different lamina thickness.
Screw (titanium alloy material ,diameter of 2.0/ 2.4/ 2.6/ 3.0mm, length of 5-11mm ,2mm interval ):
● Self-tapping design.
● Cooperate with self-supporting screw driver to facilitate screw implantation.