This bar serves to notify visitors of important updates

Products

Stay updated with the latest news, reviews, and tips. Our blog covers everything from releases and industry trends to maintenance advice and tips.

Home Products Electric Endoscopic Cutter Stapler
Electric Endoscopic Cutter Stapler
Electric Endoscopic Cutter Stapler
Electric Endoscopic Cutter Stapler
Electric Endoscopic Cutter Stapler
Electric Endoscopic Cutter Stapler
Electric Endoscopic Cutter Stapler
Electric Endoscopic Cutter Stapler
Electric Endoscopic Cutter Stapler
Electric Endoscopic Cutter Stapler
Electric Endoscopic Cutter Stapler
  • Gessure Medical

  • 1

  • ISO \ CE

  • Metal, Plastic

  • Custom service supported

  • 7–14 Days (OEM: 15–30 Days)

Inquire

Product Overview

electric endoscopic cutter stapler9.jpg

The Electric Endoscopic Cutter Stapler is a next-generation powered surgical stapling system engineered for tissue resection, transection, and anastomosis in both endoscopic and open procedures. Featuring intelligent electric drive technology, this advanced stapler delivers uniform cutting speed and smooth, burr-free incisions while effectively eliminating the manual shaking and tissue pulling commonly associated with manual staplers. The instrument incorporates structural optimizations that provide enhanced jaw pressure and superior clamping force, significantly reducing tissue slippage during firing. Available in multiple shaft lengths (S, M, L) and compatible with 45 mm and 60 mm staple cartridges featuring staple heights from 2.5 mm to 4.3 mm, the system accommodates a wide variety of tissue thicknesses. Combining power-driven precision, reliable staple formation, and comprehensive sizing options, the Electric Endoscopic Cutter Stapler delivers safe, consistent, and efficient surgical outcomes across multiple specialties.

Indications for Use

The Electric Endoscopic Cutter Stapler is indicated for the following clinical scenarios:

  • Abdominal surgery including gastric resection, colorectal anastomosis, and bariatric procedures requiring tissue division and reconstruction.

  • Thoracic surgery including lung resection, lobectomy, and esophageal surgery where precise transection and anastomosis are essential.

  • Gynecological surgery including hysterectomy and myomectomy where tissue resection and hemostasis are required.

  • Pediatric surgery for tissue resection and anastomosis in smaller patients with delicate anatomy.

  • Gastrointestinal surgery including gastrectomy, enterectomy, and colorectal cancer resection.

  • Hepatobiliary surgery for hepatic resection and biliary reconstruction.

  • Bariatric surgery including sleeve gastrectomy and gastric bypass procedures.

  • Emergency surgery where rapid, reliable tissue division and anastomosis are required.

Key Advantages

The Electric Endoscopic Cutter Stapler offers a range of distinct clinical benefits that enhance surgical precision, efficiency, and patient outcomes.

Power-Driven Precision – The electric drive technology delivers consistent, uniform cutting speed that eliminates the manual shaking and tissue pulling associated with manual staplers. The powered mechanism ensures smooth, uninterrupted tissue transection, significantly reducing the risk of tissue trauma and postoperative complications.

Enhanced Jaw Pressure – The system incorporates new structural optimizations that provide significantly greater clamping force compared to conventional staplers. This enhanced jaw pressure effectively reduces tissue slippage during firing, ensuring accurate staple placement and secure anastomosis even in challenging tissue conditions. The improved pressure is particularly advantageous in thicker tissues where secure closure is critical.

Optimized Cutting and Stapling – The uniform cutting speed produces smooth, burr-free incisions that promote optimal healing and reduce the risk of postoperative leakage. The advanced staple formation ensures consistent, reliable tissue closure, with the staples forming a perfect B-shape that provides secure hemostasis and tissue approximation.

Versatile Sizing Options – Available in three shaft lengths (S: 192 mm, M: 252 mm, L: 352 mm) to accommodate different patient anatomies and surgical approaches. The system is compatible with both 45 mm and 60 mm staple cartridges, providing flexibility for different tissue widths and resection requirements.

Comprehensive Staple Height Selection – Staple cartridges are available in five staple heights (2.5 mm, 3.5 mm, 3.8 mm, 4.1 mm, and 4.3 mm), color-coded for rapid identification and selection. This comprehensive range accommodates the full spectrum of tissue thicknesses encountered in general, thoracic, and gynecological surgery.

Superior Tissue Handling – The enhanced jaw design and optimal clamping force ensure secure tissue positioning during firing, minimizing the risk of tissue slippage and misalignment. This is particularly important in minimally invasive procedures where visualization and access are limited.

Safe and Reliable Staple Formation – The system delivers consistent, reliable staple formation across all tissue types and thicknesses. The staples are formed into a perfect B-shape that provides secure tissue approximation while maintaining adequate blood supply to the anastomotic site, promoting optimal healing and reducing the risk of leakage or stricture.

Technical Specifications & Sizing

Size Range Overview

The Electric Endoscopic Cutter Stapler System offers three shaft lengths for the stapler device and two anastomosis lengths for staple cartridges, each available in five staple heights.

Detailed Dimension Tables

Stapler Device Specifications

Product Model

Shaft Length (mm)

HP20-45S / HP22-45S

192

HP20-45M / HP22-45M

252

HP20-45L / HP22-45L

352

HP20-60S / HP22-60S

192

HP20-60M / HP22-60M

252

HP20-60L / HP22-60L

352

Note: HP20 series devices are compatible with 45 mm staple cartridges, while HP22 series devices are compatible with 60 mm staple cartridges. The S, M, and L designations correspond to shaft lengths of 192 mm, 252 mm, and 352 mm respectively.

Staple Cartridge Specifications

Cartridge Model

Staple Height (mm)

Anastomosis Length (mm)

Color Code

HP21-45W

2.5

47.2

White

HP21-45B

3.5

47.2

Blue

HP21-45D

3.8

47.2

Dark Blue

HP21-45G

4.1

47.2

Green

HP21-45T

4.3

47.2

Turquoise

HP21-60W

2.5

59.2

White

HP21-60B

3.5

59.2

Blue

HP21-60D

3.8

59.2

Dark Blue

HP21-60G

4.1

59.2

Green

HP21-60T

4.3

59.2

Turquoise

Note: Staple height selection should be based on tissue thickness assessment using the provided tissue thickness gauge. The color-coding system enables rapid identification of staple height during surgery. The cartridge is compatible with the corresponding stapler device (HP21 cartridges are designed for use with HP20 and HP22 series staplers).

The Electric Endoscopic Cutter Stapler is typically used in conjunction with the following instruments and accessories to support a complete surgical workflow:

Instrument / Accessory

Description

Key Features

Tissue Thickness Gauge

For assessing tissue thickness to select appropriate staple height

Color-coded for easy reading; single-use

Laparoscopic Graspers

For tissue manipulation and positioning during stapling

Atraumatic jaws for gentle tissue handling

Dissecting Forceps

For tissue dissection and mobilization prior to stapling

Fine tips for precise dissection

Laparoscopic Scissors

For tissue cutting and preparation

Curved and straight options available

Suction/Irrigation System

For maintaining a clear surgical field

Adjustable suction and irrigation flow

Specimen Retrieval Bag

For safe specimen extraction after resection

Various sizes available

Trocar

For establishing access for the stapler insertion

Various diameters available

Instrument Tray

For organized storage and sterile delivery

Stackable; compatible with standard sterilization

Battery/Charger System

For powering the electric stapler

Long-lasting battery; quick recharge capability

RFQ – Request for Quotation

Q1: What is the difference between the HP20 and HP22 series staplers, and when should each be used?
A: The HP20 series is designed for use with 45 mm staple cartridges, making it suitable for most standard surgical procedures requiring shorter anastomosis lengths. The HP22 series is designed for use with 60 mm staple cartridges, providing longer anastomosis length (59.2 mm) for larger tissue resections. Both series are available in the same shaft lengths (192 mm, 252 mm, and 352 mm) and feature the same electric drive technology and enhanced jaw pressure. The choice between the two depends on the anastomosis length required for the specific surgical procedure.

Q2: How do I select the appropriate staple height for a given procedure?
A: Staple height selection should be based on the thickness of the tissue being stapled. The system includes a tissue thickness gauge that allows surgeons to assess tissue thickness before selecting the appropriate staple cartridge. As a general guide: 2.5 mm staples are suitable for thin tissues (vascular, thin mesentery); 3.5 mm for medium tissues (gastric, intestinal); 3.8 mm and 4.1 mm for thick tissues (stomach, lung); and 4.3 mm for very thick tissues (obese patients, thick mesentery). The color-coding system (White, Blue, Dark Blue, Green, Turquoise) enables rapid identification and selection. Using the correct staple height is essential for achieving optimal hemostasis and tissue healing.

Q3: What is the advantage of the electric drive system over manual staplers?
A: The electric drive system provides several significant advantages over manual staplers. First, it delivers consistent, uniform cutting speed that eliminates the manual shaking and tissue pulling that can occur with manual staplers, reducing tissue trauma. Second, the power-driven mechanism ensures smooth, uninterrupted cutting and stapling, producing smooth, burr-free incisions that promote optimal healing. Third, the electric system reduces the physical effort required from the surgeon, particularly important in prolonged or complex cases. Finally, the enhanced jaw pressure, made possible by the structural optimization of the powered mechanism, provides superior clamping force that reduces tissue slippage and improves staple formation.

Q4: Can the stapler be used in both laparoscopic and open surgery?
A: Yes, the Electric Endoscopic Cutter Stapler is suitable for both endoscopic (laparoscopic and thoracoscopic) and open surgical procedures. The device is designed with a long shaft (available in 192 mm, 252 mm, and 352 mm lengths) that provides excellent reach in minimally invasive procedures, while the ergonomic handle design ensures comfortable use in open surgery. The device can be inserted through standard trocars (typically 12 mm) or used directly in open surgical fields. The 360° rotating shaft and articulating tip (on select models) further enhance accessibility in challenging anatomical locations.

Q5: Are the staple cartridges interchangeable between different stapler models?
A: The staple cartridges are designed to be compatible with specific stapler families. The HP21 series cartridges (both 45 mm and 60 mm) are compatible with the HP20 and HP22 series staplers, as well as with the disposable endoscopic stapler (HP25 series) and the powered articulating stapler (HP31 series, HP31C series). However, cartridges from different manufacturers or incompatible product families should not be used as they may not fit correctly or may compromise staple formation and patient safety. We recommend using only genuine cartridges that are specifically labeled for use with your stapler model.

Q6: What is the standard packaging configuration and shelf life for the cartridges and staplers?
A: The stapler devices are supplied non-sterile and packaged individually in protective cases, while the staple cartridges are supplied sterile, single-use, and individually packaged in sterile blister packs. The shelf life for cartridges is typically 3–5 years from the date of manufacture. We recommend checking the expiration date before use. The stapler devices are reusable after appropriate sterilization according to the manufacturer's instructions. We recommend steam sterilization at 134°C for 18 minutes. Please refer to the product labeling for specific sterilization and shelf-life information.

Related Products

    No content

Related Blogs

    No content