This bar serves to notify visitors of important updates

Products

Stay updated with the latest news, reviews, and tips. Our blog covers everything from releases and industry trends to maintenance advice and tips.

Home Intramedullary Nail Systems ld Intertan Intramedullary Nail
Intertan Intramedullary Nail
Intertan Intramedullary Nail
Intertan Intramedullary Nail
Intertan Intramedullary Nail
Intertan Intramedullary Nail
Intertan Intramedullary Nail
Intertan Intramedullary Nail
Intertan Intramedullary Nail
Intertan Intramedullary Nail
Intertan Intramedullary Nail
Intertan Intramedullary Nail
Intertan Intramedullary Nail
  • Geasure

  • 1

  • ISO \ CE \ FDA \ FSC \ MDSAP

  • Titanium Alloy

  • Custom service supported

  • 7–14 Days (OEM: 15–30 Days)

Inquire

Product Introduction

The Intertan Intramedullary Nail is designed for selected proximal femoral fracture fixation. Its 125° nail geometry, paired proximal blades, distal locking screws, end cap, and dedicated surgical instruments support controlled implantation and patient-specific orthopedic trauma planning.

Indications

The Intertan Intramedullary Nail is intended for selected proximal femoral fractures that a qualified orthopedic surgeon determines are suitable for cephalomedullary fixation. Potential applications include:

  • Selected intertrochanteric femoral fractures

  • Selected pertrochanteric fractures

  • Selected subtrochanteric fractures

  • Certain unstable proximal femoral fracture patterns

  • Fractures requiring intramedullary fixation with proximal and distal locking

  • Selected fractures requiring compression and rotational control

The nail is positioned within the femoral canal. Intertan Blade I and Intertan Blade II form the paired proximal fixation assembly, while a compatible 5.0 mm locking screw supports distal fixation.

Patient selection should consider fracture morphology, proximal fragment dimensions, femoral canal anatomy, bone quality, soft-tissue condition, previous implants, and general health. Final implant selection and surgical technique must follow the current instructions for use, applicable regulations, and professional clinical judgment.

Main Advantages

  • Integrated proximal fixation: The paired Intertan Blade I and Blade II components are designed to support controlled compression and rotational management within the femoral head and neck.

  • Consistent 125° nail geometry: All documented nail specifications feature a 125° proximal angle, supporting standardized implant and targeting-instrument selection.

  • Multiple nail dimensions: Available nail diameters include 10.0 mm and 11.0 mm, with documented lengths from 180 mm to 220 mm.

  • Graduated proximal blade options: Intertan Blade I is available from 70 mm to 100 mm, while Intertan Blade II ranges from 65 mm to 95 mm.

  • Flexible distal fixation: Compatible 5.0 mm locking screws are offered from 30 mm to 65 mm in 5 mm increments.

  • Complete implant configuration: The system includes the intramedullary nail, paired proximal blades, distal locking screws, and an M10 × 15 mm end cap.

  • Dedicated surgical instruments: A system-specific set supports entry preparation, reduction, canal reaming, nail insertion, proximal targeting, blade placement, distal locking, measurement, and extraction.

  • Coordinated canal preparation: Flexible reamer heads range from Φ9 mm to Φ12 mm, covering the documented nail diameters and supporting graduated canal preparation.

  • Clear ordering references: Individual specifications and product codes simplify hospital procurement, distributor inventory control, and medical-device traceability.

These advantages describe the system’s design and configuration. Clinical results depend on fracture reduction, implant positioning, bone quality, surgical technique, and postoperative management.

Size Parameters

Size Range

Component

Diameter or Thread

Length Range

Additional Specification

Intertan Nail

10.0-11.0 mm

180-220 mm

125°

Intertan Blade I

10.5 mm

70-100 mm

5 mm increments

Intertan Blade II

6.5 mm

65-95 mm

5 mm increments

Distal Locking Screw

5.0 mm

30-65 mm

5 mm increments

Intertan Nail End Cap

M10

15 mm

One documented size

Detailed Intertan Nail Sizes

Product

Specification

Reference Code

Intertan Nail

10.0 × 180 × 125°

15540180

Intertan Nail

10.0 × 200 × 125°

15540200

Intertan Nail

10.0 × 220 × 125°

15540220

Intertan Nail

11.0 × 180 × 125°

15541180

Intertan Nail

11.0 × 200 × 125°

15541200

Detailed Intertan Blade I Sizes

Product

Specification

Reference Code

Intertan Blade I

10.5 × 70 mm

15501170

Intertan Blade I

10.5 × 75 mm

15501175

Intertan Blade I

10.5 × 80 mm

15501180

Intertan Blade I

10.5 × 85 mm

15501185

Intertan Blade I

10.5 × 90 mm

15501190

Intertan Blade I

10.5 × 95 mm

15501195

Intertan Blade I

10.5 × 100 mm

15501200

Detailed Intertan Blade II Sizes

Product

Specification

Reference Code

Intertan Blade II

6.5 × 65 mm

15507065

Intertan Blade II

6.5 × 70 mm

15507070

Intertan Blade II

6.5 × 75 mm

15507075

Intertan Blade II

6.5 × 80 mm

15507080

Intertan Blade II

6.5 × 85 mm

15507085

Intertan Blade II

6.5 × 90 mm

15507090

Intertan Blade II

6.5 × 95 mm

15507095

Detailed Locking Screw and End-Cap Sizes

Component

Specification

Reference Code

Φ5.0 Locking Screw

5.0 × 30 mm

15405030

Φ5.0 Locking Screw

5.0 × 35 mm

15405035

Φ5.0 Locking Screw

5.0 × 40 mm

15405040

Φ5.0 Locking Screw

5.0 × 45 mm

15405045

Φ5.0 Locking Screw

5.0 × 50 mm

15405050

Φ5.0 Locking Screw

5.0 × 55 mm

15405055

Φ5.0 Locking Screw

5.0 × 60 mm

15405060

Φ5.0 Locking Screw

5.0 × 65 mm

15405065

Intertan Nail End Cap

M10 × 15 mm

15501010

The specifications and reference codes above are taken from the supplied 2026 Intramedullary Nail quotation workbook. Buyers should verify availability and current technical documentation before ordering.

A dedicated Intertan Nail Instrument Set is recommended to maintain compatibility throughout canal preparation, implant insertion, proximal fixation, distal locking, and removal.

Instrument Category

Recommended Instruments

Intended Purpose

Entry preparation

Entry guide tube, channel handle, honeycomb positioner, medullary cavity opening drill, hollow reaming drill

Establishing and preparing the nail entry path

Reduction and guidewire control

Reduction rod, ball-tipped guide pin, guide pin holder, threaded guide pin, puncture positioning stylet

Supporting fracture reduction and guidewire placement

Canal preparation

Flexible reamer rod, Φ9-Φ12 soft reamer heads, radiopaque template

Estimating nail size and preparing the femoral canal

Nail assembly and insertion

Connecting bolt, connecting bolt driver, handle, impactor, T-handle

Connecting and inserting the intramedullary nail

Proximal targeting

125° lag screw guide module, lag screw sleeve, 3.2 mm guide pin guide sleeve, puncture sleeve

Aligning the proximal blade pathway

Blade-channel preparation

Compression screw cannulated drill, compression screw drill bit, lag screw drill bit, lag screw tap, anti-rotation rod

Preparing the paired proximal fixation channels

Blade insertion

T-handle lag screw driver, compression screw driver, inner rod release driver

Inserting and controlling the proximal blade components

Depth measurement

Lag screw depth gauge, screw depth gauge

Determining appropriate blade and screw lengths

Distal locking

Positioning sleeve, drill sleeve, 4 mm bone drill, screwdriver

Preparing and inserting the distal locking screw

Extraction

Screw extractor, slide hammer, quick-change interface, universal screwdriver

Supporting implant removal when clinically indicated

Storage

Flexible reamer head box, instrument box

Organizing reusable orthopedic instruments

Before surgery, the instrument set should be inspected for completeness, cleanliness, cutting performance, connection security, targeting accuracy, and compatibility with the selected implant. Reusable instruments must undergo validated cleaning and sterilization procedures.

RFQ

What information should be included in an Intertan Intramedullary Nail RFQ?

Please provide the required nail diameter, length, quantity, Intertan Blade I sizes, Intertan Blade II sizes, distal locking screw lengths, and end-cap quantity. Buyers should also specify instrument-set requirements, destination market, regulatory documentation, packaging preferences, and delivery terms. A structured orthopedic implant RFQ helps the supplier verify component compatibility and prepare an accurate quotation.

Which Intertan Nail sizes can be quoted?

The documented Intertan cephalomedullary nail range includes 10.0 mm and 11.0 mm diameters, lengths from 180 mm to 220 mm, and a 125° proximal angle. Each required specification should be listed separately so the orthopedic implant supplier can confirm inventory, production availability, and pricing.

Which proximal fixation components should be ordered with the nail?

Buyers should request both Intertan Blade I and Intertan Blade II. Blade I has a 10.5 mm diameter and is available from 70 mm to 100 mm. Blade II has a 6.5 mm diameter and is offered from 65 mm to 95 mm. Including both components supports procurement of the complete proximal femoral fixation system.

Are distal locking screws and end caps supplied separately?

Yes. Compatible 5.0 mm distal locking screws are available in lengths from 30 mm to 65 mm. The documented Intertan Nail End Cap measures M10 × 15 mm. Hospitals and distributors should state the required quantity of every screw length and end cap in the purchase inquiry.

Can a complete Intertan Nail Instrument Set be included in the quotation?

Yes. Buyers may request a complete orthopedic surgical instrument set covering entry preparation, fracture reduction, canal reaming, nail insertion, 125° proximal targeting, blade placement, distal locking, depth measurement, and implant extraction. A complete-system quotation helps identify missing instruments before hospital procurement or distributor stocking.

Can individual replacement instruments be ordered?

Individual instruments may be requested by product name, specification, and reference code. Buyers should identify whether the item is a replacement, an additional instrument, or part of a partial set. Targeting devices, drill sleeves, drivers, and extraction tools must be confirmed as compatible with the selected Intertan intramedullary nail system.

Is OEM or private-label service available?

OEM orthopedic implant and private-label services may be discussed for eligible orders. The RFQ should identify the desired branding, label language, packaging format, estimated quantity, destination market, and documentation requirements. Any customization must comply with validated product specifications and applicable medical-device regulations.

Which regulatory and technical documents can buyers request?

Depending on availability and the destination market, buyers may request product specifications, quality-system certificates, material information, sterilization documents, packaging details, instructions for use, and relevant regulatory files. Listing these requirements in the first inquiry helps the medical-device supplier assess the project efficiently.

Can samples be requested before a bulk order?

Sample availability depends on the required implant sizes, intended evaluation, destination, and applicable regulations. Orthopedic distributors should provide company details, target market, expected annual demand, and the purpose of the sample request.

What factors determine the Intertan Nail price?

Pricing depends on nail specifications, order volume, proximal blade assortment, locking screw quantities, end caps, instrument-set configuration, sterile or non-sterile supply, packaging, certification requirements, and shipping terms. A complete bill of quantities enables a more accurate commercial offer.

What is the minimum order quantity?

Minimum order quantities may differ for cephalomedullary nails, proximal blades, distal locking screws, end caps, reusable instruments, and customized packaging. Buyers should provide an estimated order volume so the supplier can confirm the MOQ for each product category.

Can a starter inventory be quoted for an orthopedic distributor?

Yes. A starter package may include all documented Intertan Nail sizes, a practical range of proximal blades, distal locking screws, end caps, and one complete surgical instrument set. The final assortment should reflect expected procedure volume, commonly requested sizes, replenishment time, and local procurement requirements.

How can buyers receive accurate lead-time and shipping information?

Please provide the destination country, preferred Incoterms, requested delivery date, total quantity, and any sterilization or customization requirements. Lead time may vary according to stock availability, production scheduling, regulatory documentation, packaging, and transportation method.

Related Products

    No content

Related Blogs

    No content