This bar serves to notify visitors of important updates

Products

Stay updated with the latest news, reviews, and tips. Our blog covers everything from releases and industry trends to maintenance advice and tips.

Home Products linear cutter stapler
linear cutter stapler
linear cutter stapler
linear cutter stapler
linear cutter stapler
linear cutter stapler
linear cutter stapler
linear cutter stapler
linear cutter stapler
  • Gessure Medical

  • 1

  • ISO \ CE

  • Metal, Plastic

  • Custom service supported

  • 7–14 Days (OEM: 15–30 Days)

Inquire

Product Overview

endo stapler linear3.jpg

The Disposable Endoscopic Stapler is a precision-engineered surgical stapling system designed for tissue resection, transection, and anastomosis in endoscopic and open procedures across multiple specialties. Featuring a symmetrical ergonomic design that enables independent left- and right-hand operation, this versatile stapler accommodates all cartridge models with a single reusable gun body, significantly reducing surgical costs while maintaining procedural flexibility. The advanced articulating head offers 360° rotation and 45° left-right articulation, enabling optimal tissue access in challenging anatomical locations. Innovative design elements include the "Gecko Claw" surface convex pattern that minimizes staple oscillation and prevents tissue slippage during firing, as well as advanced unequal staple height technology that ensures perfect cutting and suturing while maintaining excellent blood supply to the anastomosis. Available in three shaft lengths—160 mm, 260 mm, and 360 mm—this system delivers reliable, consistent performance for a wide range of surgical applications.

Indications for Use

The Disposable Endoscopic Stapler is indicated for the following clinical scenarios:

  • Abdominal surgery including gastric resection, colorectal anastomosis, bariatric procedures, and hepatobiliary surgery.

  • Gynecological surgery including hysterectomy, myomectomy, and adnexal procedures requiring tissue resection and hemostasis.

  • Thoracic surgery including lung resection, lobectomy, and esophageal surgery where precise transection and anastomosis are essential.

  • Pediatric surgery for tissue resection and anastomosis in pediatric patients with delicate anatomy.

  • Gastrointestinal surgery including gastrectomy, enterectomy, and colorectal cancer resection.

  • Minimally invasive surgery across all specialties where endoscopic access and tissue division are required.

  • Robotic-assisted surgery as a complementary stapling system for tissue management.

  • Emergency surgery where rapid, reliable tissue division and anastomosis are required.

Key Advantages

endo stapler linear7.jpg

The Disposable Endoscopic Stapler offers a range of distinct clinical benefits that enhance surgical efficiency, safety, and patient outcomes.

Ergonomic Symmetrical Design – The stapler features a symmetrical ergonomic handle design that enables independent left- and right-hand operation, accommodating the preferences and anatomical positioning of all surgeons. This design reduces surgeon fatigue during prolonged procedures and ensures consistent, comfortable operation regardless of surgical approach or dominant hand.

Universal Cartridge Compatibility – The same gun body can adapt to all cartridge models, allowing components to be replaced during the same surgery without the need for a new instrument. This versatility significantly reduces medical costs while maintaining the flexibility to address varying tissue thicknesses and resection lengths within a single procedure.

Articulating Head with 360° Rotation – The stapler head can be rotated 360° axially and articulated 45° left and right, enabling one-time visualization and access to different tissue planes from multiple angles. This exceptional mobility is particularly valuable in complex anatomical regions where rigid instruments may not reach or align properly.

Wide Front Opening for Easy Access – The reload features a wide front opening that facilitates convenient tissue positioning and simplifies the placement of the stapler around target structures. This design reduces the time required for tissue preparation and minimizes the risk of tissue damage during positioning.

Gecko Claw Surface Convex Design – The innovative "Gecko Claw" surface convex pattern on the staple cartridge reduces lateral and longitudinal oscillation of the staples during firing. This design keeps tissue stable and prevents slippage throughout the firing process, ensuring accurate staple placement and consistent staple formation.

Advanced Unequal Staple Height Technology – The system incorporates advanced unequal staple height design that delivers perfect cutting and suturing while ensuring excellent blood supply to the anastomotic site. The graduated staple heights are optimized for different tissue layers, promoting optimal healing and significantly improving the recovery rate after surgery.

Safety Interlocking Mechanism – Equipped with safety interlocking devices that prevent the loading unit from being triggered after use, the system ensures the safety of surgical operations. This mechanism prevents accidental firing of an already-used cartridge, reducing the risk of tissue trauma and instrument malfunction.

Cost-Effective Design – The reusable gun body combined with disposable cartridges provides a cost-effective solution for surgical stapling. Hospitals can maintain a single inventory of gun bodies while stocking a variety of cartridge types, reducing overall costs and simplifying supply chain management.

 

Technical Specifications & Sizing

Size Range Overview

The Disposable Endoscopic Stapler System offers three shaft lengths to accommodate different patient anatomies and surgical approaches.

Detailed Dimension Table

Picture

Product Model

Shaft Length (mm)

endo stapler linear3.jpg

HP35-S

160

HP35-M

260

HP35-L

360

Note: The HP35 series stapler features 360° axial rotation and 45° left-right articulation of the stapler head. The S (short), M (medium), and L (long) designations correspond to shaft lengths of 160 mm, 260 mm, and 360 mm respectively. The gun body is reusable and compatible with a full range of staple cartridges, including HP31A series cartridges. The cartridge selection should be based on tissue thickness and anastomosis length requirements.

 

Picture

Specification

Staple Height (mm)

Suturing Length (mm)

Staple Quantity (pcs)

Color

linear cutter stapler cattridge6.png

HP31A-30W

2.5/2.5/2.5

31

48

White

HP31A-30R

2.0/2.5/3.0

Brown

HP31A-45W

2.5/2.5/2.5

46

66

White

HP31A-45B

3.5/3.5/3.5

Blue

HP31A-45G

4.8/4.8/4.8

Green

HP31A-45R

2.0/2.5/3.0

Brown

HP31A-45P

3.0/3.5/4.0

Purple

HP31A-45T

4.0/4.5/5.0

Black

HP31A-60W

2.5/2.5/2.5

61

90

White

HP31A-60B

3.5/3.5/3.5

Blue

HP31A-60G

4.8/4.8/4.8

Green

HP31A-60R

2.0/2.5/3.0

Brown

HP31A-60P

3.0/3.5/4.0

61

Purple

HP31A-60T

4.0/4.5/5.0

61

Black

RFQ – Request for Quotation

Q1: Can the HP35 stapler be used with all cartridge models, and what types of cartridges are available?
A: Yes, the HP35 stapler features universal cartridge compatibility, allowing the same gun body to adapt to all HP31A series cartridge models. These cartridges are available in 31 mm, 45 mm, and 60 mm anastomosis lengths, with staple heights ranging from 2.0 mm to 5.0 mm across multiple configurations (White, Blue, Green, Red, Purple, Turquoise). The cartridge selection should be based on the specific tissue thickness and resection length requirements of the procedure. This universal compatibility enables surgeons to switch between cartridge types during the same procedure without changing instruments, significantly reducing surgical time and costs.

Q2: What is the advantage of the 360° rotation and 45° articulation feature?
A: The 360° axial rotation and 45° left-right articulation provide exceptional versatility in accessing challenging anatomical locations. Surgeons can approach tissues from multiple angles without repositioning the instrument or altering the surgical approach, reducing the time required for tissue preparation and minimizing the risk of tissue damage during positioning. This feature is particularly valuable in complex procedures where access is limited or where the stapler needs to be positioned at an angle to achieve optimal tissue alignment. The wide range of motion also enhances the surgeon's ability to achieve the optimal firing angle, improving staple formation and reducing the risk of postoperative complications.

Q3: How does the Gecko Claw surface convex design improve staple performance?
A: The Gecko Claw surface convex design features a specialized pattern on the staple cartridge that reduces lateral and longitudinal oscillation of the staples during firing. This pattern creates a grip-like effect that keeps the tissue stable and prevents it from sliding during the critical firing process. This design ensures accurate staple placement and consistent staple formation, reducing the risk of staple malformation, tissue damage, and anastomotic leakage. The improved stability is particularly beneficial in thicker or more fibrous tissues where tissue slippage is more common.

Q4: What is the benefit of the advanced unequal staple height technology?
A: The advanced unequal staple height technology utilizes progressively varying staple heights along the cartridge to deliver perfect cutting and suturing while maintaining excellent blood supply to the anastomosis. The graduated staple heights are optimized for different tissue layers—shorter staples for secure hemostasis and longer staples for tissue approximation—ensuring optimal closure across the entire tissue thickness. This technology significantly improves the recovery rate after surgery by reducing the risk of ischemia, necrosis, and leakage at the anastomotic site.

Q5: What are the recommended sterilization methods for the HP35 stapler?
A: The HP35 stapler is a reusable device that can be sterilized between uses. We recommend steam sterilization at 134°C for 18 minutes, following the manufacturer's instructions for proper cleaning and maintenance. The device should be disassembled, thoroughly cleaned, and dried before sterilization to ensure effective sterilization. The stapler should be inspected for wear or damage before each use, and any damaged components should be replaced. The staple cartridges are single-use and supplied sterile; they should be discarded after each procedure.

Q6: What is the typical shelf life and storage condition for the staple cartridges?
A: The staple cartridges have a typical shelf life of 3–5 years from the date of manufacture, as indicated on the product labeling. They should be stored in a cool, dry environment away from direct sunlight and extreme temperatures. The sterile packaging should remain intact until the time of use to ensure sterility. We recommend checking the expiration date before use and disposing of any expired or damaged cartridges. For optimal performance, cartridges should be stored flat and not subjected to excessive pressure or impact that could deform the staple formation.

Related Products

    No content

Related Blogs

    No content